High quality pharma clean room manufacturer factory: Establish the use of standard operating specifications (SOP) and strict management: Items entering the clean room (aseptic room) basic requirements: All items entering the clean room (aseptic room) must be sterilized with disinfectant on the external surface in the first buffer room, and then sent to the aseptic room through the logistics buffer room, transfer window for more than 1 hour, and sterile air drying. Sterile indoor fixed items shall not be arbitrarily brought out. Personnel entering the clean room (aseptic room) requirements: experimental personnel entering the clean room (aseptic room) shall not make up, wear watches, rings and other jewelry. After cleaning your hands, you should enter the first buffer room and change your clothes. At the same time, you should change your disinfecting slippers, take off your coat, disinfect your hands with disinfectant, put on sterile gloves, change your sterile hoodie (do not expose your hair, clothes, etc.), and put on a sterile mask. Then put on a second pair of sterile gloves, and change a second pair of disinfectant isolation slippers when entering the second buffer room. Then through the air shower room 30s air shower into the sterile room. Read more details at pharma clean room.

Laboratory furniture, laboratory test equipment, including fume hood, experimental cabinet, storage cabinet, etc. According to the material classification, including all steel, all wood, steel wood, aluminum wood, stainless steel, PP and other types. For biology, medicine, coating laboratory and clean room, thorough cleaning and disinfection is the first function to be considered, which requires the laboratory furniture to be easy to clean, disinfect and keep clean for a long time.

Because of the different standards and machine styles, the die of tablet press can be divided into single tablet press die and rotary tablet press die. According to different specifications, diameter and tablet shape, the stamping dies of single stamping tablet machine and rotary tablet press can be divided into circular stamping dies and special-shaped stamping dies (triangle, oval, key type, plum blossom, rectangle, etc.), which can be customized according to your needs.

Use a Hygrometer: A hygrometer is a device that measures the current humidity level in the room. By regularly monitoring the cleanroom humidity control with a hygrometer, you can identify any fluctuations and take corrective action if necessary. Ventilation: Proper ventilation is crucial for maintaining healthy humidity levels in clean rooms. Ensure that there are sufficient exhaust fans in place to remove excess moisture and carbon dioxide from the air. Additionally, consider installing temperature and humidity sensors to monitor changes in the environment and adjust ventilation accordingly. Control Water Sources: Closely monitor water sources within the clean room, such as sinks or taps, as they can contribute to high humidity levels. Be sure to turn off faucets when not in use and avoid running water unnecessarily.

The clean room workshop is also called the dust free workshop, gmp cleanroom, the industrial clean room (Clean Room) and the dust free room. It refers to the removal of pollutants such as particles, harmful air and bacteria in the air within a certain space, and the indoor temperature,cleanliness, indoor pressure, air velocity and air distribution, noise and vibration, lighting and static control. A specially designed clean room for a particular requirement. That is to say, no matter how the extemal air conditions change, the clean room can maintain the characteristics of cleanliness temperature and humidity and pressure.

For the air outlet equipped with similar diffuser, the air volume can be found out according to the air volume resistance curve of diffuser (factory air volume resistance curve or field measured air volume resistance curve) and the measured diffuser resistance (the difference between the static pressure in the orifice and the indoor pressure). When measuring, use a micro manometer and a fine pitot tube, or use a fine rubber tube to replace the pitot tube, but the plane of the measuring hole must be parallel to the air flow direction. In addition, other methods approved by the professional testing department can also be used.

Suzhou Pharma is one of the leading turnkey project providers for pharmaceutical, food, herbal, cosmetic, electronics factory and chemical plants. We offer projects as per GMP regulations. As being pioneers in this field, the solutions from Suzhou Pharma is readily accepted by the customers. Our solid expertise in cleanroom allows meeting the precise needs of its customer’s industry in different sectors such as health,pharmaceutical, biotechnology, and cosmetics. We firmly believe in the principle of quality by design. See more details on https://www.sz-pharma.com/.

Tablet punches and dies supplier 2024: Today (Suzhou Pharma Machinery Co., Ltd.) will introduce to you, clean room airflow and influencing factors. There are many factors affecting the airflow in the clean room, such as process equipment, personnel, clean room assembly materials, lighting fixtures, etc. At the same time, the distribution point of airflow above the production equipment should also be considered.

The clean room is generally made of foam color steel or rock wool board with a vertical wall and an independent air-conditioning air supply system. The air is filtered through high-efficiency three-stage filtration in junior high schools. The personnel and materials are equipped with an air shower room and a transfer window for clean filtration.